Bimetal thermometers — Temperature

Bimetal thermometers

Instrumentation · Temperature

Manufacturer:

Nuova Fima TB8 bimetal thermometers, built entirely in stainless steel in nominal sizes of 100, 125 and 150 mm, are designed for the chemical and petrochemical industries and conventional power plants, where they must withstand the most severe ambient and process conditions. The measuring element is a bimetal spiral, and TIG welding between case and bulb strengthens the assembly and prevents leakage when the instrument is filled with damping fluid to protect it from vibration. They comply with EN 13190 with accuracy class 1, with indication ranges from -50 to +600 °C and measuring ranges from -40 to +500 °C (up to +450 °C in continuous service). The bulb is AISI 316, with diameters from 6 to 9.6 mm and immersion lengths from 100 to 900 mm, and the connection can be lower, back or every-angle, in G 1/2 A, 1/2-14 NPT or 3/4-14 NPT, fixed or sliding with swivel nut. Maximum pressure without thermowell is 15 bar and protection is IP55, or IP65/67 with glycerine or silicone oil filling. ATEX II 2G and II 2GD versions, a vented case for down to -53 °C and external zero adjustment are available. At Tecnovent we recommend combining them with a thermowell suited to your process pressure and velocity.

Request information → Download datasheet (PDF)

Technical data

Industrial sector
Chemical and petrochemical, energy, Oil & Gas, EPC
Instrument type
Bimetal thermometer
Specific applications
ATEX version, high process temperature
Conformity
EN 13190, ATEX Directive 2014/34/EU, EAC conformity
Function
Local indication
Accuracy
Class 1 to EN 13190
Material
All stainless steel
Range
-50…+600 °C (measuring -40…+500 °C)
Sensing element
Bimetal spiral
Protection degree
IP55 (IP65/67 filled version)
Nominal size
DN 100, 125 and 150 (4", 5" and 6")
Process connection
G 1/2 A, 1/2-14 NPT, 3/4-14 NPT; lower, back or every-angle; fixed or sliding
Immersion length
100…900 mm (bulb ø 6…9.6 mm)
Maximum pressure
15 bar (without thermowell)

Request a quote for this product

Tell us your application and process conditions. An engineer will reply with the right selection and pricing.

Other items